May starts the real work
AC in Logan County runs from May through September. May is when it goes from occasional use to running every day, so a weak part gets found out fast once that starts.
Takes about a minute. No obligation.
AC in Logan County runs from May through September. May is when it goes from occasional use to running every day, so a weak part gets found out fast once that starts.
A check in April catches a failing capacitor or a low charge before the system has to run on it day after day. Wait until May and the same problem shows up as a breakdown instead of something caught on a checklist.

NOAA nClimDiv, 1991–2020 normals
A dirty filter chokes the airflow across the evaporator coil, and the coil ices over instead of pulling heat out of the air.
A coil that's iced over stops cooling and can push water past the drain pan, so the fix starts with something as simple as a clean filter.




A system that never gets checked doesn't fail all at once. The capacitor weakens a little more each season until it can't kick the compressor on. Refrigerant drops slowly through a slow leak until the coil can't pull enough heat out of the air to matter. The condenser coil outside collects dirt and cut grass until the system can't shed heat as well as it needs to, so it runs longer to do the same job. None of that shows up as a single clear symptom. It shows up as a system that runs more, cools less, and then one day doesn't start.
It starts running hard in the first month of the season here. Book the check the month before.
Find a contractor
A system that still cools can still be close to a breakdown. The sound is usually the first thing to change. A hum when the compressor tries to start and can't. A rattle from a fan blade hitting loose housing. A hiss along the line that means refrigerant is getting out somewhere. Short cycling is another one. The system kicks on, runs a few minutes, and shuts off before the house feels any different. Something is telling it to stop early. Warm air out of the vents while the outdoor unit is running means it's working and getting nowhere. Ice on the line running to the outdoor unit means airflow or refrigerant is already a problem, not a warning of one to come. None of this means the system is finished. It means it's telling on itself before it quits, and a check at that point is still a repair instead of a replacement.
A tech checks refrigerant pressure against what the system is supposed to run, not just whether the air feels cold. They check the capacitor's output under load, not just whether the compressor starts today. They check the contactor points for pitting, a wiring lug starting to heat, and the condensate line for the buildup that will clog it later in the season. None of that shows up when you stand at the vent and feel the air.
Refrigerant charge and amp draw get written down, not just looked at. That number means more the second year, when a tech can see the charge dropped or the compressor is pulling harder than it used to, and catch a slow leak or a failing part before it's loud enough to notice on its own.
A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.
A tune-up starts with the filter, because nothing else works right behind a dirty one. From there a tech pulls the panel off the outdoor unit and washes the condenser coil, since caked-on dirt and grass clippings are what make the system run long and hard to move the same heat. The blower wheel gets checked for dust buildup, which throws off airflow the same way a dirty filter does. The capacitor gets tested under load, not just glanced at, because a capacitor can look fine sitting still and still fail to kick the compressor on. Refrigerant charge gets checked against what the system is rated for, and the line set gets looked over for oil residue, which is usually the first sign of a slow leak. The drain line gets cleared too, since algae and dirt build up in there over a season and back the condensate up into the pan. None of it is dramatic work. It's the same handful of checks, done the same way, so a part that's wearing out shows up on a checklist instead of in the middle of a hot stretch.